Forum Post: RE: DAC3482IZAY ESD classification

$
0
0

Hi Aaron,

Please see below for the DAC348x family device ESD rating:

DAC3484IRKDT, DAC3482IRKDT, DAC3484IZAY and DAC3482IZAY devices passed below ESD ratings.

  • ESD-HBM: +/- 500V, 1000V, 1500V, 2000V, 2500V*, 3000V*, 4000V* (Passed up to 4KV)
  • ESD-MM: +/- 50V*, 100V*, 150V*, 200V* (Passed up to 200V)
  • ESD-CDM: +/- 250, 500V, 750V*, 1000V* (passed up to 1000V).

 

DAC34H84IZAY and DAC34SH84IZAY passed below ESD ratings.

  • ESD-HBM: +/- 500V, 1000V, 1500V, 2000V (Passed up to 2KV)
  • ESD-MM: +/- 50V*, 100V*, 150V*, 200V* (Passed up to 200V)
  • ESD-CDM: +/- 250, 500V, 750V*, 1000V* (passed up to 1000V).
It seems like the customer may quality the DAC3482IZAY as class 2 ESD for their internal qualification.