Forum Post: RE: ADS1015: Question Regarding Signal Amplification and...
Hi Angel Based on my graph, the voltage varies between 1.5V and 1.8V, resulting in a delta of 0.3V. However, when I set the FSR to ±0.512V, the ADC consistently outputs the maximum value of 2047. From...
View ArticleForum Post: RE: ADS7852: Date code confirmation request from top marking (SO...
Hi Dan, Start with the second line - the '21' are year/month so this is January 2022 most likely.
View ArticleForum Post: ADC3664EVM: DCLK and Sampling Clock
Part Number: ADC3664EVM Tool/software: Dear Technical Support Team, Accoriding to userguide, DCLK and Sampling clock input level should be +10dBm. Which is correct to set sinewave(10dBm=2Vpp) or...
View ArticleForum Post: ADS131M03-Q1: could I switch off master clock but still being...
Part Number: ADS131M03-Q1 Tool/software: the idea is to provide exact number of clocks for a conversion to happen and then later get the result over SPI. Does it possible? thank you
View ArticleForum Post: ADS7052: SPI read with 24 clock cycles instead of 18 cycles
Part Number: ADS7052 Tool/software: Hello, I am wondering if it is strictly necessary to only toggle the SPI clock 18 times to take a measurement. My design has an Atmel Mega 328 which only toggles...
View ArticleForum Post: RE: ADS7052: SPI read with 24 clock cycles instead of 18 cycles
Hi Eddie, Welcome to our e2e forum! There are no issues using 24 SCLKs per transfer with the ADS7052 - all this is going to do is reduce your maximum throughput rate.
View ArticleForum Post: RE: ADS1288: ADS1288
Hi Mark, We have purchased ADS1285 kit and starting test and evaluation of geophone signals. What is your opinion about ADS1262 32bit ADC for seismic application (0.1Hz to 100Hz signals). Since...
View ArticleForum Post: RE: ADS1231: Design mistake in weight module
Hello Keith! I shorted a cable between VCC and E+ and between GND and E- and it worked! Before that I was having 0Kg all the time as conversion result. I thought the reference was connected...
View ArticleForum Post: ADS1293EVM: 5 lead Application
Part Number: ADS1293EVM Tool/software: Hello Team, Posting on behalf of my customer: I am looking forward for a 5 lead ecg setup. Generally we take reading from InA's as LA-RA. But I want a result...
View ArticleForum Post: ADS131E04: how much interface-wise ADS131E is different from...
Part Number: ADS131E04 Tool/software: if i have a driver for ADS131E could I use it for interfacing with ADS131M? thank you
View ArticleForum Post: RE: ADC12DJ5200RFEVM: Urgent Request for Correct TI-JESD204-IP...
Hi, I have received a response from the person in charge. Thank you for your support. Best regards, tabe
View ArticleForum Post: DAC39RF10EVM: No Output from GBTCLK1_FMC_p/n
Part Number: DAC39RF10EVM Other Parts Discussed in Thread: TSW14J59EVM Tool/software: Hi, We have connected the DAC39RF10EVM and TSW14J59 with the following configuration: Clocking: EXT → DACCLK |...
View ArticleForum Post: RE: DAC39RF10EVM: No Output from GBTCLK1_FMC_p/n
Hi tabe, This is as intended - the GUI does not configure the GBTCLK1 output to be enabled. This is because the TSW14J59EVM has an 1:8 buffer which duplicates the GBTCLK0 output from the DAC EVM into...
View ArticleForum Post: RE: ADS8689: ADS8689 Implementation
Hi Abhishek, I'm not quite sure what it is you are looking for here. The ADS8689 has registers that you can use to select the input voltage range, so it should be possible to (at least in part)...
View ArticleForum Post: RE: ADS131E08: Issue Utilizing the Full Range
Hi Dale, thanks for the reply. I will review this and get back to you with answers to your questions soon.
View ArticleForum Post: RE: ADS131M06-Q1: transition response
Hi YY, [quote userid="89440" url="~/support/data-converters-group/data-converters/f/data-converters-forum/1471162/ads131m06-q1-transition-response/5653634#5653634"]What the customer wants to know is...
View ArticleForum Post: RE: ADS131E04: how much interface-wise ADS131E is different from...
Hi Mykhaylo Lodygin, The ADS131E08 and ADS131M08 have pretty significant differences with respect to the digital communication and interface. I am not sure trying to turn and E08 driver into an M08...
View ArticleForum Post: RE: ADS131M03-Q1: could I switch off master clock but still being...
Hi Mykhaylo Lodygin, Can you describe the procedure you want to achieve here? I am not really following why you want to turn off the ADC clock, and then still expect the ADC to give you data "later"...
View ArticleForum Post: RE: ADS131E08: How to Suppress Industrial Frequency Noise in...
Hi Yivi Chan, I am confused about what you are trying to accomplish here: you want to both measure 50 Hz signals (presumably for metrology calculations on power lines), and also reject them? That...
View ArticleForum Post: ADS131E08: Datasheet Typo: Common-Mode Voltage
Part Number: ADS131E08 Tool/software: Hi, Is it possible that there is a typo regarding the common-mode voltage? Shouldn't it be something like (VinP + VinN) / 2 ? Thanks in Advance!