Forum Post: RE: ADS7142: ADS7142 - Two CH, Independent from External Control, Monitor

$
0
0
Hi Milorad, The input mux will change with every conversion (0 -> 1 -> 0 -> 1...), so the speed depends on the settings of the internal oscillator with the OSC_SEL and nCLK_SEL registers. See section 7.3.5 for details. Regards, Joel