Forum Post: RE: ADS1220: I need help about data rate time for Turbo Mode. Time period is smaller than conversion time in Datasheet.

$
0
0
Hi Angel, I found a problem about library which I used for ADS1220. In the process, there are two delay before and after CS Low - High operation. I changed the delay from ms to us as in the datasheet values, finally the issue resolved. Thank you very much. In my project, I will develop a board: four channel datalogger for the strain, RTD sensors and also ratiometric measurement. Firstly I designed a board which I used two ADS1220 as an ADC. 0-5V measurement, 1-128 PGA gain, 120 ohm switch selected resistors for 4-20ma current measurement. But I need help about the design. 1) When I writing code for the design I confused about the resolution of the ADS1220 is sufficient or not. In the datasheet the noise free bit is 13.42 bits in Turbo Mode and 660SPS datarate. I used digital filter: mean filter 12 reading for each channel, total readings are 24 for each ADC. The required time is about 1 / ((660/2)/12)= 36ms. The time is sufficient for my design but the noise free bit not. I need 16 bits resolution at least for each channel. Can the mean filter or other improve noise free bits? 2) Also I need 0-10V analog input for the industrial level measurement. Should I use the voltage divider and unity gain opamp? Any other suggestion. 3) Also I confused about using two or more ADC (ADS1220) each channel or multiplexing ADS1259 and PGA280-281. Is this a good choice for the 4 channel design. But In this solution I have some question: I need 1200SPS for scanning for channel and 18.4 noise free bits is enough for me but Do the gain and multiplexing stages affect this noise free bits. Also will I experience the crosstalk interference for channel to channel. In ratiometric measurement, I will switch the internal reference to the external reference. For example I connect loadcell to the channel_1, RTD to the channel_2, thermocouple to the channel_3, ... Can I change the reference ( 2.5V internal ref. to 5V external ref. and vice versa) when switching from channel to channel. Does the settling time affect the total time or SPS time? For the ratiometric measurement I will use %0.2 LDO regulator for the excitation voltage (For example 350ohm strain gauge) and external reference input but for the thermocouple I want to use 2.5V internal reference. Any other suggestion? Can I use ADS1259 internal reference to output from REFOUT pin as a sensor excitation with buffer and transistor like a linear regulator. Is this a good approach? If yes any suggestion about current limiting for the short circuit?

Viewing all articles
Browse latest Browse all 90315

Trending Articles



<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>