Dear Charles
I am using a single instance of the GUI, ok for the INT pin is set to DRDYB, one of my EVM is original, one is reworked. I am using the original for testing the GUI.
The EVM was working fine with the old EVM_GUI_1_0_2_0; today I re-installed on my laptop the new EVM_GUI_1_0_4_1, updated the firmer and the driver, restart the system, loaded the 3603.0x300_defaults.csv and Saved Values as Defaults. The register page on the GUI show the new set, but still I cannot make change on the register values, If I close and open again the GUI, the registers are not updated ( they still show Rmin= 3926.991 and Rmax= 3926.991 … ) and they do not update also by clicking on Read All button; or better: if you click several time some register come updated but probably with wrong values. The Proximity data on the GUI are showed but the inductance data are inf uH. If I use Hyper Terminal, both the Proximity data and the inductance data are showed in a correct way. For this test I also turned off the firewall and antivirus.
Thanks
Vittorio