Forum Post: RE: How to use Noise Threshold and reference Voltage for Voice Activity Detection

$
0
0

[quote user="SPalit"]

For common mode = 0.75V, 0dB full scale = 375 mVrms, -70 dB ~= 120 uVrms

[/quote]

i have a doubt here on the AGC in using the Noise Threshold, if i say -70dB and a noise less than -70dB is given input

will the AGC offer 0dB Gain or just reject the signal which is less than -70dB ?

so more over coming to my usage,trying to use AGC for noise detection what will be better settings

below are my settings

PGA gain :35dB (can i use it while using AGC for noise detection?)

Target level -5.5dBFS (now in this case my full scale voltage becomes half so my digital equivalent will not cross '(32767 / 2)' is that ?,while i have seen this practically happening my rms value of time 100ms never crossed 18K when i used AGC target level -5.5dBFS

on the other side can't i use 0dBFS in case of AGC ?

Max Gain in AGC used 35dB

20,100ms of attack and decay times

so now please suggest me a set for effective noise detection 