Forum Post: RE: Problem with LMP90100 in single scan mode.

$
0
0

Hi Mike,

Thanks for your advice - it worked well.  The conversion started immediately after entering active mode, and I didn't have to issue the RESTART command.  However, this does present a new problem for me.  In stand-by mode IB1&2 are off.  When it enters active mode it turns IB1&2 on, but the rise time is relatively slow.  Meanwhile, the conversion completes and IB1&2 is turned off again.

Is there a way of using IB1&2 in single scan mode?

Cheers,

David