Forum Post: RE: ADS1232REF drifting problem for single-ended load cell

$
0
0

Hi Bob:

Here are the answers:

1. sensor: Honeywell FS01

2. Power connection: from the terminal block +5VA to sensor +Supply, terminal block GND to sensor Ground.

3. Reference: ADS1232REF +5VA

4. Range of output code: around B73XXXXh - B74XXXXh (it is actually hard to say because the output drifts constantly)

5. data speed: I am using 80 samples/second.

6. Mode: analysis (I actually found it doesn't matter)

7. J7 and J8 are removed. Because it is a single-ended sensor, the IN1- of the terminal block is shorted with GND of the terminal block.

8. I am reading data from COM port.


Thanks!